DRAWN COPPER-NICKEL TUBES
![]() |
Standard documents:
Tubes of copper-nickel alloy grades ÌÍÆ 5-1. Specifications.
TU U 14-00195452.026-99
Alloy: ÌÍÆ 5-1 with the chemical composition of GOST 492-2006 (DSTU GOST 492:2007)
ÌÍÆ 5-1, ÌÍÆÌö 30-1-1, ÌÍÆÌö 10-1,5-0,5 with the chemical composition according to TU U 14-00195452.026-99.
Purpose: The pipes are used in the shipbuilding industry for the manufacture of condensers and heat exchangers of steam turbines.
Requirements:
Designation Standard |
Mark
|
* Outside diameter, mm |
* Wall thickness, mm |
*Pipe length, m |
Way
|
GOST 17217-79 |
ÌÍÆ 5-1 |
14-36 |
1-3 |
2000-8000 |
Pulled
|
TU U 14-00195452.026-99 |
ÌÍÆ 5-1 ÌÍÆÌö 30-1-1 |
12-30 |
1-2 |
1500-14100 |
semisolid |
ÌÍÆÌö 10-1,5-0,5 |
soft, semisolid,solid |
The geometric dimensions according to GOST 17217-79, TU U 14-00195452.026-99.
State and mechanical properties of the material:
Designation Standard |
Mark
|
Way
|
Temporary
|
Relative
|
GOST 17217-79 |
ÌÍÆ 5-1 |
Pulled (Annealed) |
255 |
30 |
TU U 14-00195452.026-99 |
ÌÍÆ 5-1 |
semisolid |
290 |
10 |
ÌÍÆÌö 30-1-1 |
semisolid |
440 |
10 | |
ÌÍÆÌö 10-1,5-0,5 |
soft |
290 |
30 | |
semisolid |
340 |
10 | ||
solid |
410 |
3 |
Mechanical properties of tubes in a solid state control in the annealed samples. Samples taken from tubes that are made in the solid state, have, after annealing in air for one hour at 650º C - 700º C.
The tubes should be sealed. Control discontinuities is performed using the eddy current flaw detector.
Other requirements according to GOST 17217-79, TU U 14-00195452.026-99.
_______________
* Requirements for the geometric dimensions of tubes negotiate with the customer when ordering.
Back to section