DRAWN COPPER RODS
![]() |
Standart documents:
GOST 1535-2006 - bars brass. Specifications
DSTU Standard 1535: 2007
TU U 27.4-00195452-015-2003 - Tubes, rods, strips and sheets made of special grades of copper.
Specifications
BS EN 12163:1998 - Copper and copper alloys. General purpose rod
DIN EN 13601:2002 - Copper and copper alloys. Rods and wires made from copper for use in electrical engineering.
Brand:
M1 M1r, M2, M2r, M3, M3r with the chemical composition of GOST 859-2001 (DSTU GOST 859:2003)
Cu-FRTP, Cu-DLP, Cu-DHP with the chemical composition of BS EN 12163:1998
Cu-FRTP, Cu-DLP, Cu-DHP, E-Cu57 TU U 27.4-00195452-015-2003
Purpose:
Normative document |
Appointment |
Standard 1535-2006 (DSTU Standard 1535:2007)
|
General-purpose rods (used in various industries). |
DIN EN 13601:2002 |
Rods are designed for use in electrical engineering. |
Shape of the section:
Normative
|
Shape of the section * |
iameter or distance between parallel faces rod *, mm |
Accuracy class |
1 |
2 |
3 |
4 |
Standard 1535-2006 (DSTU Standard 1535:2007) |
round,
|
5-50 |
– |
TU U 27.4-00195452-015-2003 |
Round |
4-50 |
– |
BS EN 12163:1998 |
round,
|
5-50 |
À, Â |
DIN EN 13601:2002 |
À, Â | ||
DIN EN 13601:2002 |
rectangular |
thickness from 5 mm to 10 mm; width from 10 mm to 120 mm |
À, Â |
Length - 1500 mm to 4000 mm *
Requirements for hire:
1. Geometric dimensions: GOST 1535-2006 (DSTU GOST 1535:2007), TU U 27.4-00195452-015-2003, BS EN 12163:1998, DIN EN 13601:2002.
2. The mechanical properties and condition of the material:
Normative
|
Mark |
The nominal diameter or distance between parallel faces of rod, mm |
State |
Temporary
|
0.2% proof stress, MPa |
Elongation A 10%, at least |
Standard 1535-2006, DSTU GOST 1535:2007 |
M1 M1r, M2, M2r, M3, M3r |
5-50 |
soft |
200 |
– |
35 |
solid |
270 |
– |
5 | |||
TU U 27.4-00195452-015-2003 |
Cu-FRTP, Cu-DLP, Cu-DHP |
4-50 |
soft |
200 |
– |
35 |
solid |
270 |
– |
5 | |||
TU U 27.4-00195452-015-2003 |
E-Cu57 |
4-50 |
soft |
200-250 |
– |
35 |
semisolid |
250-300 |
– |
10 | |||
solid |
300-360 |
– |
5 | |||
BS EN 12163:1998 |
Cu-FRTP, Cu-DLP, Cu-DHP |
5-50 |
R200 |
200 |
(80) |
35 |
5-10 incl. |
R250 |
250 |
(220) |
12 | ||
ñâ. 10-30 incl. |
R250 |
250 |
(210) |
15 | ||
ñâ. 30-50 incl. |
R230 |
230 |
(190) |
18 | ||
5-20 incl. |
R300 |
300 |
(280) |
8 | ||
ñâ. 20-40 incl. |
R280 |
280 |
(260) |
10 | ||
ñâ. 40-50 incl. |
R260 |
260 |
(230) |
12 | ||
Note. Figures in parentheses are not requirements of the standard and are given for information. |
3. Specific electrical resistance of bars mark E-Cu57 TU U 27.4-00195452-015-2003
Mark |
State |
Specific electrical resistance at 20 º C
|
E-Cu57 |
soft |
0,01754 |
semisolid |
0,01786 | |
solid |
0,01786 |
Other requirements of GOST 1535-2006, DSTU GOST 1535:2007, TU U 27.4-00195452-015-2003, BS EN 12163:1998, DIN EN 13601:2002.
______________
* Requirements for the geometric dimensions of bars agree with the customer when ordering.
Back to section