Contact wire
![]() |
Standard document:
GOST 2584-86 - contact wires of copper and alloys.
Material: copper wire rod MKLPS TU U 14-00195452.030-99.
Usage: The contact wire is used in electric power transmission.
Contact wire produced MF85 MF100.
Requirements: GOST 2584-86.
1. The geometrical dimensions of the wires.
Mark the wire |
Nominal section
|
Dimensions of wire, mm2 |
Estimated weight of 1 km of wire, kg | |||
A |
H |
C |
R | |||
MF85 |
85 |
11,76±0,22 |
10,80±0,10 |
1,3 |
6,0 |
755 |
MF100 |
100 |
12,81±0,25 |
11,80±0,11 |
1,8 |
6,5 |
890 |
Construction length: MF85 1400-2000 m
MF100 1400-1900 m
Specific electrical resistance wire DC at 20 ° C should be less than - 0.0177 × milliohms m
Mark the wire |
Ultimate Tensile, MPa |
Elongation,%
|
Number of bends in the plane of symmetry to the total destruction, not less |
The radius of the roller during the test at the bend, mm |
Maximum deviation of the radius, mm |
Number of twists shaped wire around an axis until failure, at least |
MF85 |
367,5 |
3,5 |
3 |
16 |
±1,5 |
4 |
MF100 |
362,6 |
4,0 |
3 |
16 |
±1,5 |
4 |
Surface Conditions:
The surface of the wire along the entire length should be clean and free of cracks exceeding 0.2 mm in depth. The number of defects allowed must not exceed a 2 m length of wire. The risks that go along the length of the wire should not exceed 0.1 mm in depth and number of the perimeter wire should not exceed 3. Acceptable defects include backfin, bundles, slivers, bowls, burls and risks, dents, does not take the lead for size limits in its sweep.
Packaging:
Wires should be wound on wooden drums. When winding the wire contact surface it should be towards the axis of the drum. Twisting and violation of order in the ranks of the winding is not allowed.