DRAWN COPPER RODS

DRAWN COPPER RODS


Standart documents:
GOST 1535-2006 - bars brass. Specifications
DSTU Standard 1535: 2007
TU U 27.4-00195452-015-2003 - Tubes, rods, strips and sheets made of special grades of copper.

Specifications

BS EN 12163:1998 - Copper and copper alloys. General purpose rod

DIN EN 13601:2002 - Copper and copper alloys. Rods and wires made from copper for use in electrical engineering.


Brand:
M1 M1r, M2, M2r, M3, M3r with the chemical composition of GOST 859-2001 (DSTU GOST 859:2003)

Cu-FRTP, Cu-DLP, Cu-DHP with the chemical composition of BS EN 12163:1998

Cu-FRTP, Cu-DLP, Cu-DHP, E-Cu57 TU U 27.4-00195452-015-2003


Purpose:


Normative document

Appointment

Standard 1535-2006 (DSTU Standard 1535:2007)
TU U 27.4-00195452-015-2003,
BS EN 12163:1998

General-purpose rods (used in various industries).

DIN EN 13601:2002

Rods are designed for use in electrical engineering.


Shape of the section:

Normative
document

Shape of the section *

iameter or distance between parallel faces rod *, mm

Accuracy class

1

2

3

4

Standard 1535-2006 (DSTU Standard 1535:2007)

round,
square,
Hex

5-50

TU U 27.4-00195452-015-2003

Round

4-50

BS EN 12163:1998

round,
square,
Hex

5-50

,

DIN EN 13601:2002

,

DIN EN 13601:2002

rectangular

thickness from 5 mm to 10 mm;

width from 10 mm to 120 mm

,

Length - 1500 mm to 4000 mm *


Requirements for hire:
1. Geometric dimensions: GOST 1535-2006 (DSTU GOST 1535:2007), TU U 27.4-00195452-015-2003, BS EN 12163:1998, DIN EN 13601:2002.

2. The mechanical properties and condition of the material:

Normative
document

Mark

The nominal diameter or distance between parallel faces of rod, mm

State

Temporary
resistance, MPa
at least

0.2% proof stress, MPa

Elongation A 10%, at least

Standard 1535-2006,

DSTU GOST 1535:2007

M1 M1r, M2, M2r, M3, M3r

5-50

soft

200

35

solid

270

5

TU U 27.4-00195452-015-2003

Cu-FRTP, Cu-DLP, Cu-DHP

4-50

soft

200

35

solid

270

5

TU U 27.4-00195452-015-2003

E-Cu57

4-50

soft

200-250

35

semisolid

250-300

10

solid

300-360

5

BS EN 12163:1998

Cu-FRTP, Cu-DLP, Cu-DHP

5-50

R200

200

(80)

35

5-10 incl.

R250

250

(220)

12

. 10-30incl.

R250

250

(210)

15

. 30-50incl.

R230

230

(190)

18

5-20incl.

R300

300

(280)

8

. 20-40incl.

R280

280

(260)

10

. 40-50incl.

R260

260

(230)

12

Note. Figures in parentheses are not requirements of the standard and are given for information.


3. Specific electrical resistance of bars mark E-Cu57 TU U 27.4-00195452-015-2003

Mark

State

Specific electrical resistance at 20 º C
Om ∙ mm 2, not more than m

E-Cu57

soft

0,01754

semisolid

0,01786

solid

0,01786


Other requirements of GOST 1535-2006, DSTU GOST 1535:2007, TU U 27.4-00195452-015-2003, BS EN 12163:1998, DIN EN 13601:2002.

______________

* Requirements for the geometric dimensions of bars agree with the customer when ordering.




Back to section